共计 4712 个字符,预计需要花费 12 分钟才能阅读完成。
前天 OVH 独服看到 197 Current_Pending_Sector 数值变成 1,然后用 badblock 扫描坏道果然发现了 4 个,我也没继续修复。只是开始备份数据准备找客服换硬盘。结果今天数据快拷完了重新检测了下发现 smart 197 又变成 0 了,重扫之前坏道的块也扫不到坏道了。这是怎么回事?HOH 2022-12-01 12:26 2 这个叫 unstable 251768938 2022-12-01 12:26 3 我觉得取决于扫描软件 28661 2022-12-01 12:27 4root@hostname:~# smartctl -l error /dev/sdbsmartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.0-19-amd64] (local build)Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org=== START OF READ SMART DATA SECTION ===SMART Error Log Version: 1ATA Error Count: 20 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX]Powered_Up_Time is measured from power on, and printed asDDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,SS=sec, and sss=millisec. It "wraps" after 49.710 days.Error 20 occurred at disk power-on lifetime: 19896 hours (829 days + 0 hours) When the command that caused the error occurred, the device was doing SMART Offline or Self-test. After command completion occurred, registers were: ER ST SC SN CL CH DH — — — — — — — 40 43 00 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name — — — — — — — — —————- ——————– 60 08 20 80 6a 80 40 08 42d+22:21:33.350 READ FPDMA QUEUED 61 08 28 10 9a c7 40 08 42d+22:21:30.905 WRITE FPDMA QUEUED ea 00 00 00 00 00 a0 08 42d+22:21:30.901 FLUSH CACHE EXT 60 08 00 88 0e 4c 40 08 42d+22:21:30.873 READ FPDMA QUEUED 60 08 80 80 0e 4c 40 08 42d+22:21:30.872 READ FPDMA QUEUEDError 19 occurred at disk power-on lifetime: 19896 hours (829 days + 0 hours) When the command that caused the error occurred, the device was doing SMART Offline or Self-test. After command completion occurred, registers were: ER ST SC SN CL CH DH — — — — — — — 40 43 00 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name — — — — — — — — —————- ——————– 60 08 b0 80 6a 80 40 08 42d+22:21:30.675 READ FPDMA QUEUED 60 08 08 60 0e 4c 40 08 42d+22:21:29.729 READ FPDMA QUEUED 61 08 a8 e8 27 04 40 08 42d+22:21:29.422 WRITE FPDMA QUEUED 61 08 a0 f8 27 04 40 08 42d+22:21:29.422 WRITE FPDMA QUEUED 60 08 98 38 bf f8 40 08 42d+22:21:29.343 READ FPDMA QUEUEDError 18 occurred at disk power-on lifetime: 19896 hours (829 days + 0 hours) When the command that caused the error occurred, the device was doing SMART Offline or Self-test. After command completion occurred, registers were: ER ST SC SN CL CH DH — — — — — — — 40 43 00 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name — — — — — — — — —————- ——————– 60 08 98 80 6a 80 40 08 42d+22:21:28.042 READ FPDMA QUEUED 60 08 a8 98 6e 3e 40 08 42d+22:21:25.588 READ FPDMA QUEUED 61 08 a0 28 99 c7 40 08 42d+22:21:25.588 WRITE FPDMA QUEUED ea 00 00 00 00 00 a0 08 42d+22:21:25.584 FLUSH CACHE EXT 60 08 68 50 73 f7 40 08 42d+22:21:25.535 READ FPDMA QUEUEDError 17 occurred at disk power-on lifetime: 19896 hours (829 days + 0 hours) When the command that caused the error occurred, the device was doing SMART Offline or Self-test. After command completion occurred, registers were: ER ST SC SN CL CH DH — — — — — — — 40 43 00 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name — — — — — — — — —————- ——————– 60 08 60 80 6a 80 40 08 42d+22:21:25.375 READ FPDMA QUEUED 60 08 78 78 87 3f 40 08 42d+22:21:25.364 READ FPDMA QUEUED 61 08 10 20 4c 44 40 08 42d+22:21:25.085 WRITE FPDMA QUEUED 60 08 c8 e0 16 c1 40 08 42d+22:21:24.035 READ FPDMA QUEUED 60 08 48 48 73 f7 40 08 42d+22:21:23.145 READ FPDMA QUEUEDError 16 occurred at disk power-on lifetime: 19896 hours (829 days + 0 hours) When the command that caused the error occurred, the device was doing SMART Offline or Self-test. After command completion occurred, registers were: ER ST SC SN CL CH DH — — — — — — — 40 43 00 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name — — — — — — — — —————- ——————– 60 08 78 80 6a 80 40 08 42d+22:21:22.434 READ FPDMA QUEUED 60 00 40 10 9f 22 40 08 42d+22:21:19.997 READ FPDMA QUEUED 60 00 38 10 9e 22 40 08 42d+22:21:19.997 READ FPDMA QUEUED 61 48 a8 28 98 c7 40 08 42d+22:21:19.996 WRITE FPDMA QUEUED 61 b8 70 00 58 cc 40 08 42d+22:21:19.995 WRITE FPDMA QUEUED casm 2022-12-01 12:28 5 坏道是物理损坏,只能把这片区域屏蔽掉不用。.。不会消失 猫和老鼠 2022-12-01 12:31 6 如果自己消失了你还敢用吗?主菜单 2022-12-01 12:45 7 机械一般直接屏蔽那个坏道,你扫完他就当好了 okgogogo 2022-12-01 12:52 8c5 相当大一部分都是可以自动修复,但是我有时候备份数据后一般都是标准格式化一次,一般情况下会修复这种错误,如果标准格式化没有清除这种错误,那么很大概率就是物理坏道了